Вы здесь

28.06.2016 NEXUS Online Diag Status fail

Команда show module показала fail для 5 модуля:

n7k# show module 5 Mod Ports Module-Type Model Status --- ----- ----------------------------------- ------------------ ---------- 5 48 1/10 Gbps BASE-T Ethernet Module N7K-F248XT-25E ok Mod Sw Hw --- -------------- ------ 5 6.2(2a) 1.3 Mod MAC-Address(es) Serial-Num --- -------------------------------------- ---------- 5 04-6c-9d-32-40-94 to 04-6c-9d-32-40-c7 JAE193500A0 Mod Online Diag Status --- ------------------ 5 Fail Chassis Ejector Support: Enabled Ejector Status: Left ejector CLOSE, Right ejector CLOSE, Module HW does support ejector based shutdown, Ejector policy enabled.

Это вылечилось отменой результатов теста и проведением повторного теста:

n7k# show diagnostic content module 5 Module 5: 1/10 Gbps BASE-T Ethernet Module Diagnostics test suite attributes: B/C/* - Bypass bootup level test / Complete bootup level test / NA P/* - Per port test / NA M/S/* - Only applicable to active / standby unit / NA D/N/* - Disruptive test / Non-disruptive test / NA H/O/* - Always enabled monitoring test / Conditionally enabled test / NA F/* - Fixed monitoring interval test / NA X/* - Not a health monitoring test / NA E/* - Sup to line card test / NA L/* - Exclusively run this test / NA T/* - Not an ondemand test / NA A/I/* - Monitoring is active / Monitoring is inactive / NA Testing Interval ID Name Attributes (hh:mm:ss) ____ __________________________________ ____________ _________________ 1) ASICRegisterCheck-------------> ***N******A 00:01:00 2) PrimaryBootROM----------------> ***N******A 00:30:00 3) SecondaryBootROM--------------> ***N******A 00:30:00 4) EOBCPortLoopback--------------> C**N**X**T* -NA- 5) OBFL--------------------------> C**N**X**T* -NA- 6) PortLoopback------------------> *P*N***E**A 00:15:00 7) RewriteEngineLoopback---------> *P*N***E**A 00:01:00 8) SnakeLoopback-----------------> *P*N***E**A 00:20:00 9) FIPS--------------------------> *P*NO*XE*T* -NA- 10) BootupPortLoopback------------> CP*N**XE*T* -NA-
n7k# diagnostic clear result module 5 test 1 n7k# diagnostic clear result module 5 test 2 n7k# diagnostic clear result module 5 test 3 n7k# diagnostic clear result module 5 test 6 n7k# diagnostic clear result module 5 test 7 n7k# diagnostic clear result module 5 test 8
diagnostic start module 5 test all
n7k# show module 5 Mod Ports Module-Type Model Status --- ----- ----------------------------------- ------------------ ---------- 5 48 1/10 Gbps BASE-T Ethernet Module N7K-F248XT-25E ok Mod Sw Hw --- -------------- ------ 5 6.2(2a) 1.3 Mod MAC-Address(es) Serial-Num --- -------------------------------------- ---------- 5 04-6c-9d-32-40-94 to 04-6c-9d-32-40-c7 JAE193500A0 Mod Online Diag Status --- ------------------ 5 Pass Chassis Ejector Support: Enabled Ejector Status: Left ejector CLOSE, Right ejector CLOSE, Module HW does support ejector based shutdown, Ejector policy enabled.

Добавить комментарий

Filtered HTML

  • Адреса страниц и электронной почты автоматически преобразуются в ссылки.
  • Допустимые HTML-теги: <a> <em> <strong> <cite> <blockquote> <code> <ul> <ol> <li> <dl> <dt> <dd>
  • Строки и абзацы переносятся автоматически.

Plain text

  • HTML-теги не обрабатываются и показываются как обычный текст
  • Адреса страниц и электронной почты автоматически преобразуются в ссылки.
  • Строки и абзацы переносятся автоматически.
CAPTCHA
Этот вопрос задается для того, чтобы выяснить, являетесь ли Вы человеком или представляете из себя автоматическую спам-рассылку.
Target Image