Есть cisco WS-C6509-E,
У него заняты следующие слоты:
1 WS-X6748-GE-TX 2 WS-X6748-GE-TX 3 WS-X6748-GE-TX 4 WS-X6748-GE-TX 5 WS-SUP720-3BXL 6 WS-SUP720-3BXL 7 WS-X6748-GE-TX
Соответственно есть два свободных.
Нужно добавить еще два WS-X6748-GE-TX
ru0222-serverroom2-6509-1#show power system power redundancy mode = redundant system power total = 8473.50 Watts (201.75 Amps @ 42V) system power used = 2970.24 Watts (70.72 Amps @ 42V) system power available = 5503.26 Watts (131.03 Amps @ 42V) Power-Capacity PS-Fan Output Oper PS Type Watts A @42V Status Status State ---- ------------------ ------- ------ ------ ------ ----- 1 WS-CAC-8700W-E 8473.50 201.75 OK OK on 2 WS-CAC-8700W-E 8473.50 201.75 OK OK on Pwr-Allocated Oper Fan Type Watts A @42V State ---- ------------------ ------- ------ ----- 1 WS-C6509-E-FAN 150.36 3.58 OK Pwr-Requested Pwr-Allocated Admin Oper Slot Card-Type Watts A @42V Watts A @42V State State ---- ------------------ ------- ------ ------- ------ ----- ----- 1 WS-X6748-GE-TX 432.60 10.30 432.60 10.30 on on 2 WS-X6748-GE-TX 432.60 10.30 432.60 10.30 on on 3 WS-X6748-GE-TX 432.60 10.30 432.60 10.30 on on 4 WS-X6748-GE-TX 432.60 10.30 432.60 10.30 on on 5 WS-SUP720-3BXL 328.44 7.82 328.44 7.82 on on 6 WS-SUP720-3BXL 328.44 7.82 328.44 7.82 on on 7 WS-X6748-GE-TX 432.60 10.30 432.60 10.30 on on
Т.е. каждый модуль жрет по 450 ватт, в запасе есть 5500ватт - мощностей хватает
Добавить комментарий